Personnel Protection

GROUND FAULT PROTECTION
All receptacles listed below must be protected by a ground fault circuit interrupter.
a. Sheds
b. Garage receptacles that are readily accessible
c. All receptacles in an unfinished basement or crawl space at or below grade,
with these exceptions:
1. A laundry receptacle, that is not easily accessible.
2. Single receptacles not duplex type on a dedicated circuit located and
identified for specific use by a cord and plug connected appliance such as
A freezer or refrigerator.
d. Bathroom receptacles
e. All outdoor receptacles
f. Kitchen receptacles that serve counter tops
g. All temporary construction power
h. Laundry, utility and wet bar sinks. Where the receptacles are installed within 6 feet of the outside edge of the sink.
NOTE: 15 and 20 amp 125 and 250 volt receptacles in wet locations shall have in-use covers.